CISPR 11:2015+AMD1:2016 CSV Consolidated version
作者:  日期:2016-07-08  瀏覽次數(shù):7025次  來源:
分享到:

       CISPR 11:2015+AMD1:2016 CSV 

       Consolidated version

       Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

       Abstract

       CISPR 11:2015 is available as CISPR 11:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

       CISPR 11:2015 applies to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to generate and/or use locally radio-frequency energy. This standard covers emission requirements related to radio-frequency (RF) disturbances in the frequency range of 9 kHz to 400 GHz. Measurements need only be performed in frequency ranges where limits are specified in Clause 6. For ISM RF applications in the meaning of the definition found in the ITU Radio Regulations (see Definition 3.13), this standard covers emission requirements related to radio-frequency disturbances in the frequency range of 9 kHz to 18 GHz. Requirements for ISM RF lighting equipment and UV irradiators operating at frequencies within the ISM frequency bands defined by the ITU Radio Regulations are contained in this standard. Equipment covered by other CISPR product and product family emission standards are excluded from the scope of this standard. This sixth edition cancels and replaces the fifth edition published in 2009 and its Amendment 1 published in 2010. It constitutes a technical revision. It introduces and permits type testing on components of power electronic equipment, systems and installations. Its emission limits apply now to low voltage (LV) a.c. and d.c. power ports, irrespective of the direction of power transmission. Several limits were adapted to the practical test conditions found at test sites. They are also applicable now to power electronic ISM RF equipment used for wireless power transfer (WPT), for instant power supply and charging purposes. The limits in the range 1 GHz to 18 GHz apply now to CW-type disturbances and to fluctuating disturbances in a similar, uniform and technology-neutral way. For these measurements, two alternative methods of measurement are available, the traditional log-AV method and the new APD method. It has the status of a Product Family EMC standard in accordance with IEC Guide 107, Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications (2014). This consolidated version consists of the sixth edition (2015) and its amendment 1 (2016). Therefore, no need to order amendment in addition to this publication.

       This sixth edition introduces and permits type testing on components of power electronic equipment, systems and installations. Its emission limits apply now to low voltage (LV) a.c. and d.c. power ports, irrespective of the direction of power transmission. Several limits were adapted to the practical test conditions found at test sites. They are also applicable now to power electronic ISM RF equipment used for wireless power transfer (WPT), for instant power supply and charging purposes. The limits in the range 1 GHz to 18 GHz apply now to CW-type disturbances and to fluctuating disturbances in a similar, uniform and technology-neutral way. For these measurements, two alternative methods of measurement are available, the traditional log-AV method and the new APD method.


       Introduction to Amendment 1 

       This Amendment introduces the fully-anechoic room (FAR) for measurements of the disturbance field strength in the range 30 MHz to 1 GHz on equipment in the scope of CISPR 11.

It contains the complete set of requirements for measurement of radiated disturbances from equipment fitting into the validated test volume of a given FAR. It specifies a separation distance of 3 m and restricts use of the FAR to measurements on table-top equipment. 

       At the moment the FAR can be used: 

       ? for measurements on table-top equipment fitting into the validated test volume of the given FAR, 

       ? for a separation distance of 3 m only, and 

       ? if the FAR was validated according to CISPR 16-1-4. 

       The limits for class A and class B group 1 equipment in this CDV base on the limits in the generic emission standards IEC 61000-6-3:2006/AMD 1 (2010) and IEC 61000-6-4:2006/AMD 1 (2010). The limits for class A and class B group 2 equipment were derived using the same approximation formula as used when deriving the limits for the generic emission standards in mid of the years 2000 to 2010. CISPR/H/104/INF, published in 2005, gives detailed explanations how these limits for the FAR were derived. 

       More detailed background information is still found in CISPR/B/627/CDV. CISPR/B WG1 in October 2015

       增加了30MHZ~1GHz全電波暗室測試附錄

       更多行業(yè)信息盡在3ctest/泰思特官方網(wǎng)站>>>>>>>http://www.replicastee.com;歡迎來訪!

上一篇:電磁干擾對軍用器械的危害...
下一篇:ACMA decision
·【 泰思特電子云講堂 】雷達(dá)罩...
·蘇州泰思特電子被選舉為江蘇省航...
·干貨分享 | 汽車電子拋負(fù)載測...
----------------------------
·探討電磁干擾的危害與電磁兼容技...
·IEC61000-4-5:20...
·新能源汽車線束布置方案及EMC...
----------------------------
·新品發(fā)布:沖擊電流模擬器 S0...
·新品發(fā)布:阻尼正弦瞬態(tài)信號發(fā)生...
·新品發(fā)布:差模傳導(dǎo)干擾模擬器 ...
----------------------------
·泰思特2018年展會信息一覽表...
·泰思特2017年展會信息一覽表...
·泰思特2016年展會信息一覽表...
----------------------------